{"id":8247,"date":"2020-11-10T20:20:09","date_gmt":"2020-11-10T19:20:09","guid":{"rendered":"https:\/\/webentwicklung-hess.com\/kiesewetter2023\/produkt\/ask-541-4\/"},"modified":"2024-11-22T10:55:06","modified_gmt":"2024-11-22T09:55:06","slug":"ask-541-4","status":"publish","type":"product","link":"https:\/\/mbs-ag.com\/en\/produkt\/ask-541-4\/","title":{"rendered":"ASK 541.4"},"content":{"rendered":"
Therm. nominal continuous current Icth: 1,0 x Ipr Therm. nominal short-time current Ith: 60 x Ipr, 1 Sek. Max. operating voltage Um: 0,72 kV Isolation test voltage: 3 kV, Ueff, 50 Hz, 1 Min. Nominal rated frequency: 50\/60 Hz Isolation class: E<\/p>\n","protected":false},"featured_media":8260,"template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[670],"product_tag":[],"class_list":{"0":"post-8247","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ask-plug-in-current-transformer","7":"pa_accuracy-class-1783","8":"pa_accuracy-class-02s","9":"pa_accuracy-class-673","10":"pa_accuracy-class-675","11":"pa_application-industrial-application","12":"pa_burden-va-125","13":"pa_burden-va-998","14":"pa_burden-va-126","15":"pa_burden-va-127","16":"pa_burden-va-261","17":"pa_burden-va-128","18":"pa_burden-va-129","19":"pa_burden-va-130","20":"pa_burden-va-15-2","21":"pa_burden-va-4279","22":"pa_burden-va-1488","23":"pa_bus-bar-1-in-mm-40x10","24":"pa_bus-bar-2-in-mm-2x30x5","25":"pa_depth-in-mm-101","26":"pa_group-ask","27":"pa_group-code-1-678","28":"pa_messung-1-phasig","29":"pa_primary-current-833","30":"pa_primary-current-679","31":"pa_primary-current-369","32":"pa_primary-current-370","33":"pa_primary-current-254","34":"pa_primary-current-255","35":"pa_primary-current-220","36":"pa_primary-current-221","37":"pa_primary-current-222","38":"pa_primary-current-680","39":"pa_primary-current-223","40":"pa_primary-current-111","41":"pa_primary-current-112","42":"pa_primary-current-113","43":"pa_primary-current-114","44":"pa_primary-current-115","45":"pa_primary-current-116","46":"pa_primary-current-117","47":"pa_primary-current-118","48":"pa_round-conductor-in-mm-604","49":"pa_rverwend_2-123","50":"pa_sealed-shutters-110","51":"pa_secondary-current-135","52":"pa_secondary-current-136","53":"pa_snap-on-mounting-2615","54":"pa_system-plug-in-current-transformer-closed","55":"pa_transformer-height-600","56":"pa_transformer-width-8176","57":"pa_type-2-541-4","58":"pa_web-artikel-212","60":"first","61":"instock","62":"shipping-taxable","63":"purchasable","64":"product-type-variable","65":"entry","66":"content-bg","67":"loop-entry"},"acf":[],"taxonomy_info":{"product_cat":[{"value":670,"label":"ASK plug-in current transformer"}],"pa_accuracy-class":[{"value":1783,"label":"0,2"},{"value":672,"label":"0,2S"},{"value":673,"label":"0,5"},{"value":675,"label":"1"}],"pa_application":[{"value":671,"label":"Industrial application"}],"pa_burden-va":[{"value":125,"label":"1"},{"value":998,"label":"1,25"},{"value":126,"label":"1,5"},{"value":127,"label":"2,5"},{"value":261,"label":"3,75"},{"value":128,"label":"5"},{"value":129,"label":"7,5"},{"value":130,"label":"10"},{"value":131,"label":"15"},{"value":4279,"label":"20"},{"value":1488,"label":"30"}],"pa_bus-bar-1-in-mm":[{"value":607,"label":"40x10"}],"pa_bus-bar-2-in-mm":[{"value":609,"label":"2x30x5"}],"pa_depth-in-mm":[{"value":101,"label":"58"}],"pa_group":[{"value":677,"label":"ASK"}],"pa_group-code-1":[{"value":678,"label":"201,202"}],"pa_messung":[{"value":109,"label":"1-phasig"}],"pa_primary-current":[{"value":833,"label":"30"},{"value":679,"label":"40"},{"value":369,"label":"50"},{"value":370,"label":"60"},{"value":254,"label":"75"},{"value":255,"label":"80"},{"value":220,"label":"100"},{"value":221,"label":"125"},{"value":222,"label":"150"},{"value":680,"label":"160"},{"value":223,"label":"200"},{"value":111,"label":"250"},{"value":112,"label":"300"},{"value":113,"label":"400"},{"value":114,"label":"500"},{"value":115,"label":"600"},{"value":116,"label":"750"},{"value":117,"label":"800"},{"value":118,"label":"1000"}],"pa_round-conductor-in-mm":[{"value":604,"label":"32"}],"pa_rverwend_2":[{"value":123,"label":"1"}],"pa_sealed-shutters":[{"value":110,"label":"59042"}],"pa_secondary-current":[{"value":135,"label":"1"},{"value":136,"label":"5"}],"pa_snap-on-mounting":[{"value":2615,"label":"55012"}],"pa_system":[{"value":210,"label":"Plug-in current transformer (closed)"}],"pa_transformer-height":[{"value":600,"label":"98,5"}],"pa_transformer-width":[{"value":8176,"label":"86"}],"pa_type-2":[{"value":663,"label":"541.4"}],"pa_web-artikel":[{"value":212,"label":"1"}]},"featured_image_src_large":["https:\/\/mbs-ag.com\/en\/wp-content\/uploads\/sites\/2\/2023\/12\/PB_ASK541.4.jpg",600,600,false],"author_info":[],"comment_info":"","_links":{"self":[{"href":"https:\/\/mbs-ag.com\/en\/wp-json\/wp\/v2\/product\/8247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mbs-ag.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/mbs-ag.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mbs-ag.com\/en\/wp-json\/wp\/v2\/media\/8260"}],"wp:attachment":[{"href":"https:\/\/mbs-ag.com\/en\/wp-json\/wp\/v2\/media?parent=8247"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/mbs-ag.com\/en\/wp-json\/wp\/v2\/product_cat?post=8247"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/mbs-ag.com\/en\/wp-json\/wp\/v2\/product_tag?post=8247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}